Exam text content

DEE-34016 Modeling and Control of Electric Drives - 15.03.2017 (Tentti, Rekola)

Exam text content

The text is generated with Optical Image Recognition from the original exam file and it can therefore contain erroneus or incomplete information. For example, mathematical symbols cannot be rendered correctly. The text is mainly used for generating search results.

Original exam
Tampere University of Technology 15.3.2017
Electrical Energy Engineering DEE-34016 Modeling and Control of Electric Drives

Jenni Rekola Programmable calculator allowed 5 guestions/ ä 6 p
Answers in English or in Finnish allowed
1. Propositions
Answer, if the following propositions are true or not true. Correct answer 1p, wrong answer -1p.

o The rotor structure presented in Fig. 1 is used in salient-pole permanent magnet synchronous
machine.

 

Fig. 1. Rotor

b) Stator resistance value has a major effect to the accuracy of the speed estimation.
c) The modulation method has an effect on the peak value of the common mode voltage pulse.
d) Flux density distribution is assumed sinusoidal in the air gap of a machine when space vector
theory is used
Stator resistance of a slip-ring machine can be changed
N PMSM machine is modeled usually in rotor reference frame.

2. DC machine

N, * Draw the eguivalent circuit of a separately exited DC machine

J vw the control block diagram of separately exited DC machine with speed control and
shortly explain the figure (2p)

c) What means electrical time constant of DC machine, how it is defined?

The load torgue of the uncontrolled separately excited machine is decreased step-wisely
from its nominal value to 0,5*nominal torgue in the nominal operating point. How the
rotational speed, armature current and magnetizing current change? Why?
The magnetizing voltage of the uncontrolled separately excited DC machine decrease step-
wisely from its nominal value to 0,5*nominal voltage when the motor rotates at its nominal

speed without the load. How the rotational speed, armature current and magnetizing current
change? Why?

102)

 
Tampere University of Technology 15.3.2017
Electrical Energy Engineering DEE-34016 Modeling and Control of Electric Drives

Jenni Rekola Programmable calculator allowed 5 guestions/ ä 6 p
Answers in English or in Finnish allowed

3. Permanent magnet synchronous machine (PMSM)

What is the difference in the mechanical structure of salient and non-salient PMSM machines?
How the torgue production of these two machines differs from each other?

J How the control method of these two machines differs from each other?
What are the benefit/benefits of PMSM compared to induction machine?
What are the drawback/drawbacks of PMSM compared to induction machine?

da The speed reference of the controlled, non-salient PMSM is increased step-wisely from its
nominal value to 1.5*nominal speed when the torgue reference is nominal. How the produced
torgue and stator current (d- and g-component) change? Why?

4. Reluctance machine

X Describe shortly the operation principle of reluctance machine
2) How torgue is produced in reluctance machine?
c) How torgue is controlled?
d) What are the benefit/benefits of reluctance machine?
e) What are the drawback/drawbacks of reluctance machine?
f) Why the magnetized assisted reluctance machine is used in electric vehicles instead of
conventional reluctance machine?

5. Induction machine

Explain the operation principle of direct torgue control (DTC).

Which parameters need to be measured from the motor drive when DTC is used?
c) Why the adaptive motor model is needed in the control system?
d) What are the benefits of DTC compared to scalar (Volts/Hz) control?

J Wi are the most important un-idealities which might affect to the operation of the real-world
motor drive control system, but which are not usually taken into account in the ideal simulation
models?

The measured torgue and torgue reference of an induction machine are shown in Fig. 2. Analyze
the differences of FOC and DTC. The switching freguency of FOC is 1.3 kHz and the average
switching freguency of DTC is the same.

 

 

Torgue (Nm)

 

jm 95 18 195 2 28 20 25 286 (ja vs os os o2 me o ommoo 28 a

Fig. 2. a) Torgue reference and measured torgue with FOC (field oriented control i.e. vector control)
and b) torgue reference and measured torgue with DTC

202)

 


We use cookies

This website uses cookies, including third-party cookies, only for necessary purposes such as saving settings on the user's device, keeping track of user sessions and for providing the services included on the website. This website also collects other data, such as the IP address of the user and the type of web browser used. This information is collected to ensure the operation and security of the website. The collected information can also be used by third parties to enable the ordinary operation of the website.